From FELIX Laboratory wiki
Beam | |
Energy | 12–25 MeV |
---|---|
Undulator | |
period (λu) | 65 mm |
no. periods | 42 |
no. poles | 84+2 |
gap (range) | 22.6–110 |
KRMS (range) | 0.4–2.08 |
undulator type | PPM |
magnet type | SmCo |
FELIX-1, or FEL1, is the far-infrared or long-wavelength beam line of FELIX operating from 30–140 µm.
Spectral Range vs. Beam Energy
Beam Energy [MeV] | Min [µm] | Max [µm] | Min [cm-1] | Max [cm-1] | Max pulse width [µs] | Max power [mJ@µm] |
---|---|---|---|---|---|---|
16.6 | - | - | - | - | 12 | |
17.7 | - | - | - | - | 12 | |
18 | - | - | - | - | 12 | |
19 | 33 | 110 | 91 | 303 | 12 | 28 @ 42 |
19.6 | 28 | 111 | 90 | 360 | 12 | 45 @ 42 |
20.5 | 34 | 100 | 100 | 294 | 12 | range needs verification |
22 | 28 | 66 | 151 | 360 | 12 | range needs verification |
26 | 18 | 33 | 300 | 555 | ? | 65 @ 24 |
Parameters
Cavity Mirrors
Upstream
The default upstream mirror is M5. For long wavelengths, one of the stronger focussing mirrors M2 or M3 may be selected.
Mirror | Range (µm) | Offset (µm) |
---|---|---|
M1 - | - | - |
M2 R=2400 | > 120 | 95 |
M3 R=2650 | > 90 | 260 |
M4 - | - | - |
M5 R1=R2 | < 110 | 0 |
Downstream
Check the table for a downstream proper mirror. Mirrors with larger holes will have smaller gain (and therefore slower rise of the optical pulse), but will emit more light at larger wavelengths.
Mirror | Range (µm) | Offset (µm) |
---|---|---|
M1 4mm R=2250 | > 90 | 310 |
M2 5mm R=2250 | > 100 | 170 |
M3 2mm | 20–40 | 150 |
M4 3mm | 30–70 | 20 |
M5 4mm | 50–110 | 0 |
The position of the cavity zero detuning length should be -840 µm from the positive limit for mirror combination M5/M5. N.B. on 2022/07/11 the cavity zero was +480 µm more than it should have been according to these values. To be checked on the next occasion.
Undulator
See feluc.