This page contains important remarks or problems that need to be noted by the operators.

Timing_1_KHz_to_or_from_500_Hz

Date Operator State Issue Solution Subsystem
2018-10-29 Victor Solved FLARE undulator wouldn't move, PXI-7330 (2) firmware out of date Updated firmware of PXI-7330 (2) via MAX, reinitialized PXI-7330 (2) with settings 20180328, restarted service FLARE undulator Undulator
2018-09-29 Victor Notice The pyro signal has been digitized, there is a GUI to run on your desktop if you want, see: Pyrod Diagnostics
2018-08-30 Victor Solved Interferometer FEL 2 data invalid Adjusted aligment inside the vault and removed 3rd harmonic filter but issue still occurs with 900mV signal Cavity
2018-08-01 Bryan Active Heater turning off Reset heater error Klystron
2018-08-02 Bryan Solved Klystron West Technix 2 trouble Put in spare oiltank transformer Modulator
2018-08-03 Lex Solved Dipole FEL2 terminals welded together Released the terminals magnet works again. Beam Optics
2018-08-06 Bryan Solved P70 uitgevallen en wou niet aanblijven Protection uitgezet en pomp opnieuw opgestart, pomp moet uitgestookt worden Vacuum
2018-08-06 Bryan Solved 2P30 uitgevallen Error gereset en controller weer opgestart, en klep upstream tank weer opengestuurd Vacuum